XR100 Series Programming Guide Digital Monitoring Products
25
SyStem RepoRtS
7.13.2
REMOTE CHANGE
Remote Change Port
ThisoptiondisplayswhenNETisselectedforSendLocalChanges.EnterthePort
number.Validnumbersarefrom0to65535.Defaultis2002.
7.13.3 Remote Telephone Number
ThisoptiondisplayswhenDDisselectedforSendLocalChanges.PressCOMMANDto
enter the phone number the panel dials when sending programming changes. After
enteringaphonenumber,thepanelsendsanypanelchangestoRemoteLink.
Thephonenumbercanhavetwolinesof16characterseachtoequal32.Entera
P to program a two second pause in the dialing sequence. The P character counts
aspartofthe32allowablecharacters.Enter*70Pasthestringrstcharactersto
cancel call waiting. Dial tone detect is an automatic panel function.
System Reports
8.1
SYSTEM REPORTS
System Reports
Selectspecicsystemreportsthepanelsendstothereceiver.
8.2
ABORT NO YES
Abort Report
YES allows the panel to send an alarm abort report to the receiver any time an
area is disarmed during Transmit Delay before an alarm report is sent and the Bell
Cutoff Time has not expired. After disarming an area, if any other area remains
armedandhaszone(s)inalarm,thealarmabortreportisnotsent.
If the communication type is set to DD, a Warning: Alarm Bell Silenced report is
also sent if the alarm bell is silenced.
Note:AbortReportsarenotsentforFire,FireVerify,orSupervisorytypezones.
8.3
RESTORAL: YES
Restoral Reports
This option allows you to control when and if a zone restoral report is sent to the
central station receiver. Press any Select key to display the following options:
NO YES DISARM
NO -Disablesthezonerestoralreportoption.Zonescontinuetooperatenormally
but do not send restoral reports to the receiver.
YES -Enablesthezonerestoralreportoption.Zonerestoralsaresentwhenevera
zone restores from a trouble or alarm condition.
DISARM -Causesthepaneltosendrestoralreportsforanon-24-hourzone
whenever a zone that has restored from a trouble or alarm condition is disarmed.
All24-hourzonessendrestoralreportsastheyrestore.
Note: For UL applications, Restoral Reports must be set to YES.
8.4
BYPASS NO YES
Bypass Reports
YES allows the panel to send all zone bypasses, resets, and force arm reports to
the receiver. The bypass report includes the zone number, zone name, and the user
name and number of the individual operating the system. Reports are only sent if
O/CUserinCommunicationsissetYESforReceiver1orReceiver2.
8.5
SCHD CHG NO YES
Schedule Change Reports
YES allows the panel to send all schedule changes to the receiver. The report
includes the day, opening time, closing time, extend schedule time, and the user
name and number of the individual making the change. Schedule changes made
throughRemoteLink™arenotsenttotheprinterorDisplayEvents.
8.6
CODE CHG NO YES
Code Change Reports
YESallowsthepaneltosendallcodeadditions,changes,anddeletionstothe
receiver. The code change report includes the user name and number added or
deleted and the user name and number of the individual making the change. Code
changesmadethroughRemoteLink™arenotsenttotheprinterorDisplayEvents.
ReportsareonlysentifO/CUserinCommunicationsissetYESforReceiver1or
Receiver2.ThedefaultsettingisYES.