XR100 Series Programming Guide Digital Monitoring Products
19
Device Setup
6.14
OVERRIDE NO YES
Schedule Override
UsethisoptiontoallowdoorON/OFFschedulestobeoverriddenbythearmedcondition
of the system. Selecting YES causes the on time for a door schedule to be ignored when
all areas assigned to Access Areas for this device are armed. Should any area become
disarmed after the door schedule on time, the device output turns on. A door output
which is on during a disarmed period automatically turns off when all access areas
assigned to the device become armed, even if the scheduled off time has not been
reached. This feature can be used to keep doors locked when a factory opens late, or
is forced to close early, due to a snow storm or other cause. Select NO to allow door
schedules to operate independent of system armed status.
Note: When OVERRIDE is YES and there are no areas programmed in ACCESS AREAS,
thedoorscheduleforthatdevicedoesnotwork.EithersetOVERRIDE to NO or enter an
area number in ACCESS AREAS.
6.15 Auto Force Arm Device?
Select YES to have all Display Areas assigned to this keypad automatically arm and force
arm faulted zones at arming. The user is not prompted to select areas to arm or force
arm faulted zones after choosing ARM at the keypad. If Closing Code is programmed as
YES,onlythematchingareasbetweentheDisplayAreasandtheUserCode’sauthorized
areas arm. Also, when YES is selected, the user is not prompted to select areas to
disarmafterenteringacodeatEntryDelayorafterchoosingDisarmatthekeypad.
AllmatchingareasassignedtotheUserCodeandtothiskeypadareautomatically
disarmed. When NO is selected,theuserispromptedtoselectareas(ALLNOYES)and
choose to force arm or bypass at arming and disarming. Default is NO.
6.16 Door Real-Time Status?
Select YES tohavereal-timedoorstatusmessagessenttoPCLogreportingandEntré
reporting for this device. Messages are sent anytime the panel turns the door relay on
or off. Default is NO.
6.17 Send Door Forced Message?
Select YES tohavethepanelsendareal-timedoorstatusmessageofForcedOpen(FO)to
PCLogreportingandEntréreporting
when the door relay is off, but the door zone has
transitioned from its normal state. Default is NO.
6.18 Program 734/734N Options
Select YES toprograma734ora734N/734N-WiFiWiegandInterfaceModule.Theoptions
displayedfora734ora734N
are the same.
Toprograma734,theDevicetypemustbesettoDOORandtheDeviceCommunication
TypemustbesettoKPDBUS.
Toprogramthe734N/734N-Wi,theDeviceTypemustbesettoDOORandtheDevice
CommunicationTypemustbesettoNETWORK.
6.18.1 Activate Zone 2 Bypass
SelectYEStoactivatetheBypassoption.
SelectingNOallowsstandardzoneoperationonZone2anddisplaystheACTIVATEZONE
3REXoption.DefaultsettingisNO.
Ifthedoorbeingreleasedbythe734/734N\734N-WiFimoduleisprotected(contact
installed),youcanprovideaprogrammableBypassentry/exittimerbyconnectingits
contactwiringtoa734/734N/734N-WiFimoduleZone2.Whentheon-boardFormCrelay
activatesandtheuseropensthedoorconnectedtoZone2,thezoneisbypassedforthe
numberofsecondsprogrammedinZONE2BYPASSTIMEallowingtheusertoenter/exit.
IfZone2doesnotrestore(doorclosed)withintheprogrammedbypasstime,the
734/734N/
734N-WiFi
piezopulsesduringthelasttenseconds.IfZone2restoresprior
to the end of the programmed time, the piezo silences. If the zone does not restore
beforetheprogrammedtime,the734/734N/
734N-WiFi
ends the bypass and indicates
the open or short zone condition to the panel.
6.18.2
ZONE 2 BYPASS
TIME: 40
Zone 2 Bypass Time
EnterthenumberofBypasssecondstoelapsebeforetheBypasstimerexpires.Rangeis
from20to250seconds.Pressanytoprowselectkeytoenterthenumberofseconds.
Ifthedoorremainsopenwhenthetimerexpiresazoneopen/shortissenttothepanel
forZone2.Thedefaultis40seconds.
6.18.3
RELOCK ON ZONE 2
CHANGE? NO YES
Relock on Zone 2 Change?
SelectingNOleavestherelayonwhenZone2faultstoanopenorshortcondition
duringBypass.SelectingYESturnsthe734/734N/
734N-WiFi
relayoffwhenZone2
changes state. The default is NO
AUTO FORCE ARM
DEVICE? NO YES
DOOR REAL-TIME
STATUS? NO YES
SEND DOOR FORCED
MESSAGE? NO YES
PROGRAM 734
OPTIONS? NO YES
ACTIVATE ZONE 2
BYPASS? NO YES