Digital Monitoring Products XTL Series Installationsanleitung

Stöbern Sie online oder laden Sie Installationsanleitung nach Sicherheitszugriffskontrollsysteme Digital Monitoring Products XTL Series herunter. Digital Monitoring Products XTL Series Installation guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - PROGRAMMING GUIDE

PROGRAMMING GUIDEXTL/XTLC CONTROL PANEL

Seite 2 - MODEL XTL/XTLC

XTL/XTLC Programming Guide Digital Monitoring Products3INTRODUCTION1.6 Keypad Connect up to four DMP 9060 and 9063 Wireless LCD Keypads to the XTL/XT

Seite 3 - TABLE OF CONTENTS

Digital Monitoring Products XTL/XTLC Programming Guide4INTRODUCTION1.9 Entering Non-Alpha CharactersTo enter a space in an alpha entry, press the 9

Seite 4

XTL/XTLC Programming Guide Digital Monitoring Products5INITIALIZATIONInitialization2.1 InitializationThis function allows you to set the panel’s prog

Seite 5

Digital Monitoring Products XTL/XTLC Programming Guide6COMMUNICATIONCommunication3.1 CommunicationThe Communication section allows you to congure th

Seite 6

XTL/XTLC Programming Guide Digital Monitoring Products7COMMUNICATION3.10 Second GPRS APN (XTL Only)Enter the second APN (Access Point Name). This wo

Seite 7

Digital Monitoring Products XTL/XTLC Programming Guide8COMMUNICATION3.24 Test ReportYES enables the Recall Test report to be sent to this receiver.

Seite 8 - Introduction

XTL/XTLC Programming Guide Digital Monitoring Products9MESSAGING SETUPMessaging Setup4.1 Messaging SetupThis section allows you to enter the informa

Seite 9 - 1.5 Reset Timeout

Digital Monitoring Products XTL/XTLC Programming Guide10MESSAGING SETUParming/disarming authorization.4.10 O/C EmailSelect YES to allow the panel to

Seite 10 - 1.7 Special Keys

XTL/XTLC Programming Guide Digital Monitoring Products11DEVICE SETUPDevice Setup5.1 Device SetupThis section allows you to dene the panel wireless

Seite 11

Digital Monitoring Products XTL/XTLC Programming Guide12Remote Options6.1 Remote OptionsThis section allows you to enter the information needed for

Seite 12 - Initialization

Digital Monitoring Products XTL/XTLC Programming GuidebMODEL XTL/XTLC CONTROL PANEL PROGRAMMING GUIDEWhen using the XTL/XTLC control for any listing

Seite 13 - Communication

XTL/XTLC Programming Guide Digital Monitoring Products13SYSTEM REPORTSSystem Reports7.1 System ReportsThis function allows you to select the reports

Seite 14

Digital Monitoring Products XTL/XTLC Programming Guide14SYSTEM OPTIONSSystem Options8.1 System OptionsThis section allows you to select system wide

Seite 15

XTL/XTLC Programming Guide Digital Monitoring Products15SYSTEM OPTIONS8.7 Cross Zone TimeEnter the time allowed between zone faults. When a zone pro

Seite 16 - Messaging Setup

Digital Monitoring Products XTL/XTLC Programming Guide16SYSTEM OPTIONS8.13 Time Zone ChangesThis option allows the panel to request automatic time c

Seite 17 - 4.10 O/C Email

XTL/XTLC Programming Guide Digital Monitoring Products17SYSTEM OPTIONS8.17 Occupied PremisesSelect YES to allow the panel to automatically disarm th

Seite 18 - Device Setup

Digital Monitoring Products XTL/XTLC Programming Guide18BELL OPTIONSBell Options9.1 Bell OptionsThis section allows you to program the panel bell ou

Seite 19 - Remote Options

XTL/XTLC Programming Guide Digital Monitoring Products19OUTPUT OPTIONSOutput Options10.1 Output OptionsThis section allows you to program output opt

Seite 20 - System Reports

Digital Monitoring Products XTL/XTLC Programming Guide20OUTPUT OPTIONS10.9 Disarmed OutputThis output/Favorite turns on when all areas of the panel

Seite 21 - System Options

XTL/XTLC Programming Guide Digital Monitoring Products21OUTPUT INFORMATIONOutput Information11.1 Output InformationThis section allows you to progra

Seite 22 - ARM ACTY DAYS: 0

Digital Monitoring Products XTL/XTLC Programming Guide22AREA INFORMATIONArea Information12.1 Area InformationThis section allows you to assign funct

Seite 23

XTL/XTLC Programming Guide Digital Monitoring ProductsiTABLE OF CONTENTSIntroduction ...11

Seite 24

XTL/XTLC Programming Guide Digital Monitoring Products23ZONE INFORMATION Zone Information13.1 Zone InformationThis allows you to dene the operation

Seite 25 - Bell Options

Digital Monitoring Products XTL/XTLC Programming Guide24ZONE INFORMATION13.4 Zone NamePress any Select key to display the default zone name. To chan

Seite 26 - Output Options

XTL/XTLC Programming Guide Digital Monitoring Products25ZONE INFORMATION The ability to stop the arming does not apply if a wireless arming device is

Seite 27

Digital Monitoring Products XTL/XTLC Programming Guide26ZONE INFORMATIONThis option displays when programming an 1114 zone expander which provides fo

Seite 28 - Output Information

XTL/XTLC Programming Guide Digital Monitoring Products27ZONE INFORMATION 13.11 Series Key FobsOnly zones 31-34 or 41-44 can be programmed as 1100 Se

Seite 29 - Area Information

Digital Monitoring Products XTL/XTLC Programming Guide28ZONE INFORMATIONAction options. To view more options press the COMMAND key.ARM (Arm) - Arms s

Seite 30 - Zone Information

XTL/XTLC Programming Guide Digital Monitoring Products29ZONE INFORMATION PLS (Pulse) - The output alternates one second on and one second off.MOM (Mo

Seite 31

Digital Monitoring Products XTL/XTLC Programming Guide30ZONE INFORMATION13.13.3 Output ActionEntering an Output Number displays this option that all

Seite 32 - 13.10 Contact

XTL/XTLC Programming Guide Digital Monitoring Products31ZONE INFORMATION If no other cross-zoned zone in the system trips before the cross-zone time

Seite 33

Digital Monitoring Products XTL/XTLC Programming Guide32Stop14.1 StopAt the STOP option, pressing any Select key allows you to exit the programmer fu

Seite 34

Digital Monitoring Products XTL/XTLC Programming GuideiiTABLE OF CONTENTSMessaging Setup ...94.1

Seite 35 - Output Action

XTL/XTLC Programming Guide Digital Monitoring Products33APPENDIXAppendixThis section of the XTL/XTLC Programming Guide provides additional zone and s

Seite 36 - 12.13.2 Output Number

Digital Monitoring Products XTL/XTLC Programming Guide34APPENDIXCell Roaming Indicator on XTLCThe Cellular Signal Strength option in the panel’s Diag

Seite 37

XTL/XTLC Programming Guide Digital Monitoring Products35APPENDIX16.5 Using the 984 Command FunctionThis feature allows the integrity of the cellular

Seite 38 - ZONE NO:

Digital Monitoring Products XTL/XTLC Programming Guide36APPENDIX16.7 Keypad Speaker OperationWhen using LCD Keypads, the panel provides distinct spe

Seite 39 - Set Lockout Code

XTL/XTLC Programming Guide Digital Monitoring Products37APPENDIXStyleTGL ARM DIS STEP MNTTGL * Outputs = 31 to 34, or 41 to 44. = This function not

Seite 40 - Appendix

Digital Monitoring Products XTL/XTLC Programming Guide3816.9 Zone Type DefaultsThe XTL/XTLC panel contains 11 default zone types that provide the mo

Seite 41

XTL/XTLC Programming Guide Digital Monitoring Products3916.10 Common Keypad MessagesMessage Meaning Possible SolutionsINVALID CODEThe user code you

Seite 42

Digital Monitoring Products XTL/XTLC Programming Guide40REVISIONSRevisions to This DocumentThis section explains the changes made to this document du

Seite 43 - 16.9 Zone Type Descriptions

XTL/XTLC Programming Guide Digital Monitoring Products41

Seite 44 - XTL/XTLC Zone Information

LT-1108 1.07 © 2015 Digital Monitoring Products, Inc.15105800-641-4282www.dmp.comDesigned, Engineered and Assembled in USAINTRUSION • FIRE • ACCESS •

Seite 45 - 16.9 Zone Type Defaults

XTL/XTLC Programming Guide Digital Monitoring ProductsiiiTABLE OF CONTENTSBell Options ...1

Seite 46

Digital Monitoring Products XTL/XTLC Programming GuideivTABLE OF CONTENTS13.10.3 Disarm/Disable ...

Seite 47 - Revisions to This Document

XTL/XTLC Programming Guide Digital Monitoring ProductsvTABLE OF CONTENTS Failed Zones Display...3516.

Seite 48

XTL/XTLC Programming Guide Digital Monitoring Products1INTRODUCTIONIntroduction1.1 Before You BeginBefore starting to program, we recommend you read

Seite 49 - Certications

Digital Monitoring Products XTL/XTLC Programming Guide2INTRODUCTIONYou are now ready to start programming the XTL/XTLC panel. Pressing the COMMAND ke

Kommentare zu diesen Handbüchern

Keine Kommentare