Digital Monitoring Products Canadian XR100 Bedienerhandbuch Seite 31

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 78
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 30
XR100 Series Programming Guide Digital Monitoring Products
23
Remote options
7.6
PC MODEM NO YES
PC Modem
YESallowsthepaneltoanswerthetelcolinkandconnectwithRemoteLink
throughthePCModemat2400baud.NOdisablesPCModemcommunication.
7.7
ALR RCVR NO YES
Alarm Receiver Authorization
SelectYEStoenableremotecommandsandprogrammingtobeacceptedfromthe
alarmSCS-1RReceiver.TheRemoteKeyoptioncanalsoberequired.
WithYESselected,thepanelrequeststhereceiverkeyduringitsrstcommunication
withtherstSCS-1RReceiver.Thepanelretainsthisalarmreceiverkeyinmemoryand
allows remote commands to be accepted from the alarm receiver. If an alarm occurs
during a remote connect, the alarm report is immediately sent to this receiver only.
When NO is selected, remote commands and programming are not accepted from the
alarmSCS-1RReceiver.
7.8
SVC RCVR NO YES
Service Receiver Authorization
YESenablesremotecommandsandprogrammingtobeacceptedfromasecondary
servicereceiverotherthanthealarmSCS-1RReceiver.TheRemoteKeyoptioncanalso
be required.
WithYESselected,thepanelrequeststheservicereceiverkeythersttimeitis
contacted by the service receiver. The panel retains this service receiver key in memory
and accepts remote commands from the service receiver.
If an alarm occurs during a remote connect, the panel disconnects from the service
receiver and calls the alarm receiver. Alarm reports are only sent to the alarm receiver.
It is important that the alarm receiver key and the service receiver key programmed
at the central station are NOT the same so the panel can determine the difference
between receivers.
When NO is selected remote commands and programming are not accepted from a
secondary service receiver.
ThisoptionmustbeYEStoallowprogrammingfromadirectlyconnectedcomputeror
aniCOM/iCOM-E.
7.9 Manufacturer Authorization
SelectYEStoallowDMPTechnicalSupporttechnicianstoaccessthepanelduring
system service or troubleshooting. This authorization automatically expires within
one hour.
DMP remote service is provided on a read only basis: DMP technicians can look
at the system programming and make suggestions only. Alterations can only be
accomplished by installing company service personnel.
7.10 Allow Network Remote
Thisoptiondisplaysonlyifthepanelhasnetworkcapability.YESallowsremote
programming over the network. Changing this option does not change any other
networkprogrammingoptions.DefaultisYES.
7.10.1
NETWORK PROG
Network Programming Port
PORT: 2001
Entertheprogrammingportnumber.Theprogrammingportidentiestheportused
to communicate messages from the panel. The default Programming Port setting is
2001.
7.10.2 Encrypt Network Remote
YESencryptsdatasentovernetwork.DefaultisNO.
7.11 Allow Cellular Remote
YESallowsremoteprogrammingusingcellularconnection.DefaultisYES.
7.11.1 First GPRS APN
EntertherstAPN(AccessPointName).Thisallowsanaccesspointforcellular
communication and is used to connect to a DNS network. The APN may contain two
linesof16characterstoequal32characters.DefaultissettoSECURECOM400.
Second GPRS APN
EnterthesecondAPN(AccessPointName).Thisworksasabackupincasetherst
APNfails.TheAPNmaycontaintwolinesof16characterstoequal32characters.
DefaultissettoSECURECOM400.
SECURECOM400
-
FIRST GPRS APN
AUTH? NO YES
ALLOW NETWORK
REMOTE? NO YES
MANUFACTURER
ENCRYPT NETWORK
REMOTE? NO YES
ALLOW CELL
REMOTE? NO YES
SECURECOM400
-
SECOND GPRS APN
Seitenansicht 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 ... 77 78

Kommentare zu diesen Handbüchern

Keine Kommentare