XR150/XR350/XR550 Series Programming Guide Digital Monitoring Products
63
APPENDIX
22.12.1
Keypad Bus Zone Type Defaults
These are complete spellings of the abbreviations used for the zone types, such as Night and Exit.
Type - These are the abbreviations used for the zone types, such as NT and EX.
Area - For an Area or Home/Sleep/Away with Guest system this is 1 to 32. For an All/Perimeter or Home/
Sleep/Away system, this is the Interior, Bedroom, or Perimeter. Select the area for NT, DY, EX, A1, A2, and AR
types.
Fire Bell Out - Only available for FI, FV, and SV zones. Use any output zone number listed.
Message - A = alarm report, T = trouble report, L = local, no report, (dash) = no report, D = door propped
(When SV zone is connected to 303 Silence/Reset Switch), S = sensor reset/alarm silence,
C = early morning ambush cancel.
Output - These are 1 to 6 on-board and 500 to 999 off-board relay outputs, 450 to 474 and 480 to 499 wireless
outputs, D1 to D16, F1 to F20, and G1 to G20.
Action - This selects the action of the output: S = steady, P = pulse, M = momentary, and F = follow
Swinger - The zone can be automatically bypassed after a programmed number of trips.
Prewarn - This selects the keypad address that sounds the entry prewarn for this zone.
Entry Delay - This is the entry delay timer selected as the default for this zone.
Retard Delay - Provides a programmed retard time before an alarm initiates from a shorted zone. When used
on an arming zone, the retard delay occurs when the zone is shorted before the armed state has changed.
If the arming zone has Maintain as the Style, the retard delay also occurs when the zone returns to a normal
state.
Presignal - Provides a keypad tone for zones in retard delay. Retard must be YES before Presignal can be
selected.
Fast Response - Provides a 167ms zone response instead of the normal 500ms response.
Cross Zone - Provides cross zoning with any of the 574 zones.
Priority - Requires this zone to be in a normal condition before the area can be armed.
Style - The abbreviations for arming zone style:
TGL = Toggle, ARM = Arm only, DIS = Disarm only, STEP = Wireless arming, MNT = Maintain