DMP Wireless
For a DMP 1100X Wireless Receiver set the House Code from 1 to 50. See House Code programming in System
Options. Zones 500 through 999 can be programmed as Wireless zones. Briey reset the panel using the J16 jumper
to activate Wireless operation. Refer to the XR150/XR350/XR550 Series Installation Guide (LT-1233).
For an 1100 Series Key Fob see section 18.11.
NOTE: All wireless programming is stored in the panel. The 1100X Wireless Receiver obtains the necessary
programming information from the panel each time the receiver powers up, when the programmer STOP routine is
selected or the panel is reset. The receiver memory refresh takes up to 10 seconds to complete depending on the
number of wireless zones programmed and the Red LED remains on during this time. Normal receiver operation is
inhibited during the memory refresh period.
18.10 Wireless
Select YES to program this zone as a DMP wireless zone. You must program the wireless
House Code prior to adding DMP wireless zones to the system.
See House Code programming in System Options. Default is NO.
18.10.1 Serial Number Entry
Enter the eight-digit serial number found on the wireless device.
This message displays when the serial number is already programmed for another zone.
The programmed zone number displays.
18.10.2 Contact
This option displays if the serial number entered is for an 1101, 1103, or 1106 Universal
Transmitter or 1114 Wireless Four-Zone Expander. Press any top row key to select the
contact.
This option displays when programming an 1101, 1103, or 1106 Transmitter. Select INT to
use the internal reed switch contacts. Select EXT to connect an external device to the
1101, 1103, or 1106 terminal block. Default is INTERNAL.
By allowing both of the transmitter contacts (INT and EXT) to be used at the same
time, two zones may be programmed from one transmitter. When using both contacts,
you must use consecutive zone numbers. Zones 531 and 532 or zones 890 and 891 are
acceptable zone assignments.
For example, program transmitter serial number 01345678 as Zone 521 with an INT
contact type and Zone 522 with an EXT contact type. The same serial number is used for
both zones.
This option displays when programming the 1114 Wireless Four-Zone Expander with four
input contacts. The same serial number is used for all four contacts. Select the contact
number to program. When using the contacts, you must use consecutive zone numbers.
Default is Contact 1.
For example, use serial number 08345678 to program Contact 1 for Zone 561, Contact 2
for Zone 562, Contact 3 for zone 563, and Contact 4 for zone 564.
A tamper on the 1114 is transmitted as the zone number assigned to Contact 1.
This message displays when the Contact is already programmed for another zone. The
programmed zone number displays.
This option only displays when EXT is selected as the Contact type. For external devices
connected to the 1101, 1103 or 1106 terminal block, select NO to use normally closed
(N/C) contacts. Select YES to use normally open (N/O) contacts.
Default is NO.
18.10.3 Supervision Time
Press any top row key to select the supervision time required for the wireless zone. Press
COMMAND to accept the default time. Default is 240 minutes.
Note: Refer to the Wireless Check-in and Supervision Time Denitions section of the
Appendix for supervision information.
Press the Select key under the required number of minutes. The transmitter must check
in at least once during this time or a missing condition is indicated for that zone. 1100
Series transmitters automatically checkin based on the supervision time selected for
the wireless zone, no additional programming is needed. If two zones share the same
transmitter, the last programmed supervision time is stored as the supervision time for
both zones. Zero (0) indicates an unsupervised transmitter.
ZONE INFORMATION
WIRELESS? NO YES
TRANSMITTER
SERIAL#: XXXXXXXX
ALREADY IN USE
ZONE NUMBER: XXX
TRANSMITTER
CONTACT:XXXXXXXX
TRANSMTR CONTACT
INT EXT
TRANSMTR CONTACT
1 2 3 4
ALREADY IN USE
ZONE NUMBER: XXX
ZONE INFORMATION
NORM OPN NO YES
TRANSMITTER
SUPRVSN TIME: 240
SELECT MINUTES:
0 3 60 240