1912XR Installation Guide
Digital Monitoring Products, Inc. 1912XR Installation Guide
Page 21
Common
Normally Closed
Normally Open
Device Fail LED
OR
1k
Voltage Output
from 1912XR
Voltage Output
from 1912XR
Terminal 10 of
the 1912XR
Terminal 10 of
the 1912XR
+
+
Used to indicate Device Failure
Figure 10: Device fail output configuration
24.7 Keypad 4-wire bus
The keypad and loop expander 4-wire bus must be run entirely in conduit and remain inside the same room
as the panel, unless an external communication fail indicator is added. A 12 VDC relay may be wired as a
communication failed indicator. Connect the positive side of the indicator to one of the voltage outputs and
the negative side to keypad ground (terminal 10) of the 1912XR. See section 14.2.
In addition to the wiring above, the device fail output must be programmed to activate the appropriate
voltage output. See Section 8.5L of the 1912XR Programming Manual (LT-0171).
24.8 Local Protective Signaling Systems
The DMP Model 866 Indicating Circuit Module must be used on the bell circuit for detection of shorts and
grounds. See sections 26.1 to 26.3 for wiring diagrams. An alphanumeric keypad must be used for local
systems.
24.9 Proprietary Protective Signaling Systems
The total number of panels assigned to one multiplex receiving line of the DMP SCS-1 Receiver system
must not exceed 90. This may be increased to 180 by setting the SNRM option to NO in the SCS-1
Receiver system. This is to allow any report from a 1912XR to be sent to the receiver within 90 seconds.
24.10 Remote Station Protective Signaling Systems
You must provide 60 hours of standby battery. Up to four 12 VDC, 6.5Ah batteries may be used along with
a 16 VAC, 100VA transformer (DMP Model 322). See section 7.6 for standby battery calculations. Two
Radionics Model D127 Reversing Relay Modules provide two reversing polarity telephone connections.
See section 26.5 and the D127 Installation Instruction sheet for wiring details. A DMP Model 893 must be
used to provide two line dialer communication or Type 1 Multiplex communication.
CALIFORNIA STATE FIRE MARSHAL SPECIFICATIONS
25.1 Bell output definition
The bell output of the Model 1912XR must be programmed to operate steady on burglary alarms and
pulsed on fire alarms. See sections 8.4A and 8.4B of the 1912XR Programming Manual (LT-0171).