Digital Monitoring Products 1912XR Installationsanleitung Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
Digital Monitoring Products, Inc. 1912XR Installation Guide
Page 14
1912XR Installation Guide
12 VDC Outputs 3 to 6
14.1 Description
Four 12 VDC, 50mA voltage outputs are provided on the panel's J2 Output Harness to power external relay
coils or other low power indicators. The voltage outputs can be operated by all of the same functions as
Relay Outputs 1 and 2.
When connecting any devices to outputs 3 to 6, subtract the current draw of the device from the panel's
available auxiliary power.
14.2 Harness wiring
To use the voltage outputs on the panel, install a DMP 304 Harness (available separately) onto the 10-pin
header labeled J2. The wire harness descriptions are shown below:
Output Color Harness Wire
3 White/Brown 4
4 White/Red 3
5 White/Orange 2
6 White/Yellow 1
Devices connected to the outputs must be located within the same room as the 1912XR panel.
Telephone RJ Connector
15.1 Description
Connect the panel to the public telephone network by installing a DMP 356 RJ Cable between the panel's
J3 connector and the RJ31X or RJ38X phone jack. Set the 3-pin headers labeled J11 and J12 on the
1912XR to DD for dialer or DDMX operation or MPX for multiplex operation.
15.2 FCC registration
The Model 1912XR complies with FCC part 68 and is registered with the FCC. Registration number:
CCKUSA-18660-AL-R Ringer Equivalence: 1.3B
15.3 Notification
Registered terminal equipment must not be repaired by the user. In case of trouble, the device must be
immediately unplugged from the telephone jack. The factory warranty provides for repairs. Registered
terminal equipment may not be used on party lines or in connection with coin telephones. Notification must
be given to the telephone company of:
a. The particular line(s) the service is connected to
b. The FCC registration number
c. The ringer equivalence
d. The make, model, and serial number of the device
15.4 Ground start
For ground start operation, install the DMP 305 Relay into socket K2.
1
2
3
4
5
6
7
8
Tip 1
Tip
Ring
Ring 1
To TELCO Line
To Premises Phone
Place a jumper across
terminals 2 and 7 to provide
phone jack supervision. Loss
of the jumper shows as a
phone trouble on the
Security Command keypad
display.
RJ31X or RJ38X
phone jack
Figure 8: Phone jack wiring