Seitenansicht 8
N/A = No Information Available
DMP XR500/XR500N/XR500E
The DMP XR500, XR500N, and XR500E Command Processor™ Panels provide dealers and end-users with an integrated feature package. With an extensive feature set this panel the obvious choice for all your burglary, re, and access control applications.
The XR500 Series provides 10 on-board zones, up to 574 programmable zones, 574 programmable outputs, 502 programmable Form C relays, and 10,000 User Codes with 99 separate proles. The XR500N and XR500E offer on-board network support.
The XR500E also offers built-in Encryption and secure passphrase option. Program common areas, cross-zoned areas, primary and secondary schedules, temporary and permanent schedules, output schedules, and view a history of up to 12,000 events.
Compatible with the complete line of DMP 1100X Series Two-Way Wireless, providing support for up to 500 DMP Wireless devices.
Compares to:
Ademco Vista-128BP, Vista-250BP
DSC MAXSYS PC4020
Bosch D9412GV2
GE AL-4017 Alliance
GE Interlogix Concord Ultra, Advent 60-562-01, NX-8E
Pacom 1057, 1058
FBII XL-5
DMP XR500 DMP XR500N/ XR500E Bosch D941GV2
GE
AL-4017
Alliance
Ademco
Vista-128BP
Ademco
Vista-250BP
FBII XL-5
GE
Interlogix
Concord
Ultra
GE Interlogix Advent
60-562-01
GE Interlogix
NX-8E
DSC MAXSYS
PC4020
Pacom
1057
Pacom
1058
Zone Information
Maximum Zones
574 574 246 256 128 250 128 96 250 192 128 256 256
Control Panel Zones
10 10 8 16 8 8 8 8 8 8 16 N/A 8
Control Panel Fire Zones
2 2 0 N/A 2 2 N/A 1 1 N/A N/A None None
Hardwired Expansion Zones
564 564 238 240 120 242 120 96 242 184 112 N/A 255
Wireless Expansion Zones
DMP 1100 Series
(500 Zones)
DMP 1100 Series
(500 Zones)
238 N/A
128 UL Listed for
Commercial
Burg and Fire
250 UL Listed for
Commercial
Burg and Fire
N/A 96 250 192 64
Requires
1066-INOV
Module
N/A
Powered Smoke Zones
2 onboard
560 off-board
2 onboard
560 off-board
Requires D125B Powered
Loop interface module
N/A 2 2 N/A 1 1 N/A
4-wire from
SAUX
None None
Maximum 2-Wire Smoke Detectors
12 (521B) per zone,
Maximum 562 zones = 6,744
Detectors
(Requires 715 Zone
Expanders for off-board
zones) Up to 500 (521LX)
addressable Smokes
12 (521B) per zone,
Maximum 562 zones = 6,744
Detectors
(Requires 715 Zone
Expanders for off-board
zones) Up to 500 (521LX)
addressable Smokes
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Keypad/Access Information
Max Supervised Keypads
16 16 8 16
16 Keypads or
6 touch screen
keypads
16 Keypads or
6 touch screen
keypads
16
SuperBus 2000
Devices up
to 16
Up to 31 SuperBus 2000
Devices per Bus no
more than 62 per panel.
These include keypads,
Zone Expanders, Output
modules, etc.
32 unknown if all are
supervised
16 8 16
Max Unsupervised Keypads
Unlimited Unlimited 32 0 N/A N/A N/A N/A N/A N/A N/A N/A N/A
Doors of Access
16 16 8
16 standard
expandable
to 64
8 doors
expandable to
16 using Vista
Gateway Module
15 doors N/A N/A N/A N/A
Up to 16 dual
reader modules
for a total of
32 readers
64 16
Wiegand Input Keypads
Yes Yes 0 Yes N/A N/A N/A N/A N/A N/A N/A Yes Yes
Fully Keypad Programmable
Yes Yes No No N/A N/A Yes Yes Yes N/A Yes Yes Yes
Keypad Compatible with all Products
Yes Yes No No N/A N/A N/A N/A N/A N/A N/A N/A N/A
Power & Output information
Auxiliary Power
1.5A 1.5A 1.4A 300mA 1A 1A 900mA 1.35A 5A
2A-unknown if
shared w/Bell output
500mA shared
with SAUX
2A N/A
Bell Power
1.5A 1.5A 2A N/A
2.3A divided
between two
bell circuits
2.3A divided
between two
bell circuits
2A
12 Watt Siren
driver
Siren Driver output 4.8
Ohms at 25 Watts
N/A 700mA 2A N/A
Auxiliary Output
2 Form “C” 4 Open Collector
outputs onboard expandable
to 500 outputs offboard
2 Form “C” 4 Open Collector
outputs onboard expandable
to 500 outputs offboard
2 onboard Form C and
expandable off board to
126 for 128 relays overall
16 onboard
expandable
to 256
1 onboard
expandable to
96 relays
1 onboard
expandable to
96 relays
8 voltage trigger
outputs 40
programmable
relay outputs
2 4 N/A 64
64 Form C
64 Open
Collector
64 Form C
64 Open
Collector
DMP Product Comparisons Guide Digital Monitoring Products
8
COMPARISONS NOte