N/A = No Information Available
DMP XRSuper6
The XRSuper6 is designed for home and small business installations. The panel is expandable to 22 zones, either through wireless or hardwire, has superior false alarm reduction, and 60-event memory capability.
Compares to:
Ademco Vista P
FBII XL-20
DSC Classic PC1550, Power 432, PC1616
Napco XP400
Bosch D4412
GE Networx NX-4, Networx NX-6, Concord Express
Moose ZX200
DMP XRSuper6
Ademco
Vista-P
FBII XL-20
GE Networx
NX-4
GE Networx
NX-6
DSC Classic
PC1550
DSC Power 432 DSC PC1616 Bosch D4412 Napco XP400 Moose ZX200
GE Concord
Express
Zone Information
Maximum Zones
22 22 8 8 12 6 32 (Wireless) 16 24 4 8 24
Control Panel Zones
6 6 4 4 6 6 4 6 8 4 w/ Zone Doubling 4 6
Control Panel Fire Zones
1 0 0 1 1 0 N/A N/A 1 0 See Powered Smoke Zones 1
Hardwired Expansion Zones
16 16 0
4 w /Zone
Doubling
6 w/Zone
Doubling
0 4 16 16 0 4 w/ Zone Doubling 18
Wireless Expansion Zones
16 16 8-5800 Series
8 w/ Zone
Doubling
16 0 32 16 24 4 w/ Zone Doubling 8 w/ Zone Doubling 16
Powered Smoke Zones
1 0 1 1 1 0 N/A N/A 1 0 1 1
Keypad/Access Information
Max Supervised Keypads
4 4 4 8 16 3 8 8 8 4 4 4
Max Unsupervised Keypads
Unlimited 0 0 0 0 0 0 0 0 0 0 0
Doors of Access
4 0 0 0 0 0 0 0 0 0 0 0
Wiegand Input Keypads
Yes No No No No No N/A No No No No No
Fully Keypad Programmable
Yes Yes Yes Yes Yes Yes N/A Yes Yes Yes Yes Yes
Keypad Compatible with all Products
Yes Yes No No No No N/A No No No No Yes
Power & Output Information
Auxiliary Power
600mA 500mA 500mA 400mA 400mA 475mA N/A 550mA 600mA 750mA 500mA 750mA
Bell Power
1.5A 2A 1A 2.5A 2.5A 1A N/A 700mA 1.85A 2A 1.5A 1.25A
Auxiliary Output
4 fully programmable 4 4 4 4 1 N/A 3 4 expandable to 12 1 See Powered Smoke Zones 2
User Information
User Codes/Access Cards
16 16 6 8 40 6 32 + Master Code 32 + Master Code 32 4 9 16
Event Memory
60 32 90 185 185 Last Alarm Only 128 500 254 Last Alarm Only 30 50
Event Sort
First/Last/Scroll-
Keypad
0 Software only
Keypad & Soft-
ware
Keypad &
Software
Keypad Keypad Keypad Keypad Keypad Keypad Keypad
Pager Direct
Yes Yes No Yes Yes No No No No Yes Yes Yes
Latchkey Paging
Yes No No Yes Yes No No No No No Yes Yes
2 Way Voice
Yes Yes Yes Yes Yes No
Requires PC5950
Module
Requires PC5900
Module
Yes Yes No Yes
Individual Zone Monitor
Yes No No No No No N/A Yes Yes No No No
DMP Product Comparisons Guide Digital Monitoring Products
11