Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide
36
aPPendiX
Appendix
This section of the XRSuper6/XR20/XR40 Programming Guide provides additional zone and system
information.
14.1 Status List
The Status List is the current status of the system or records of recent system events that display on
alphanumeric keypads. For example, in Home/Away systems you may see the display SYSTEM READY.
If an event were to occur on the system, such as an AC failure, the keypad would also display the AC
POWER -TRBL message. This is a system event that is placed into the Status List to alert the user to a
problem with the system.
Some Status List items remain in the display until manually cleared and some are cleared automatically
when the condition returns to normal. Below is a list of status and event displays the keypad can show in
the Status List:
Description Must be manually cleared?
Fire and Supervisory zone alarms Yes - by Sensor Reset
Fire and Supervisory zone troubles No - clears when zone restores
Burglary zone alarms No - clears at disarming.
All other zone alarms No - clears when zone restores
Zone monitor displays No - clears after approximately 8 minutes
Day zone alerts No - clears after approximately 8 minutes
System monitor troubles No - clears when condition restores
(AC and battery trouble)
Armed status display No
(System On)
Disarmed status displays No
(System Ready, System Not Ready)
Remote keypad messages No
(Sent to the keypad by your ofce or central station)
Each item in the list is displayed for four seconds. When there are multiple items in the list, you can use
the COMMAND or Back Arrow keys to scroll forward or back through the items.
14.2 False Alarm Reduction
System Recently Armed report
The System Recently Armed report (S78) is sent when a burglary zone goes into alarm within two minutes
of the system being armed.
14.3 Numeric Pager Message Formats
The following example shows individual pager display components:
Pager Display — 00128–20010001
00128 = account number 2 = Message ID 0 = Always zero 010 = Area number 001 = User number
Message ID Descriptions
1 = Zone Alarm 2 = Zone Trouble 3 = Areas Arming 4 = Areas Disarming
5 = Late to Close 6 = User Check-in 7 = Local Message
The examples below show a typical display for each of the pager report options:
Zone Alarm Zone Trouble Areas Arming Areas Disarming User Check-in
00128–10003 00128–20010 00128–30123001 00128–40123001 00128–60008
Communication Attempts
Only one pager signal is sent to the pager terminal equipment at a time. For each pager message
to be sent, the panel dials the rst phone number and follows the steps detailed in the Receiver 2
Programming and Pager Type sections.