Seitenansicht 17
Installation
XRSuper6/XR20/XR40 Installation Guide
14
Digital Monitoring Products www.dmpnet.com 2500 N. Partnership Boulevard Springfield, MO 65803
UL 1023 SPECIFICATIONS
Household Burglar-Alarm System Units
16.1 Bell cutoff
The bell cutoff time cannot be less than five minutes. See the XRSuper6/XR20/XR40 Programming Guide (LT-
0305).
16.2 Entry delay
The maximum entry delay used must not be more than 45 seconds. See the XRSuper6/XR20/XR40 Programming
Guide (LT-0305).
16.3 Exit delay
The maximum exit delay used must not be more than 60 seconds. See the XRSuper6/XR20/XR40 Programming
Guide (LT-0305).
16.4 Zone expansion on 4-wire bus
When expansion zones are used, the keypad and zone expander 4-wire bus must be limited to three feet in
length unless an external communication fail indicator is added. A 12 VDC relay may be wired as a
communication fail indicator. To install, connect the negative side of the indicator to one of the panel's
annunciator outputs and the positive side to the smoke power (terminal 11 of the panel). See the XRSuper6/
XR20/XR40 Programming Guide (LT-0305).
In addition to the wiring described above, a 24-hour zone must be programmed to activate the appropriate
annunciator output.
UL 1610 and 1076 SPECIFICATIONS
Central-Station and Proprietary Burglar-Alarm Units
17.1 Opening/Closing reports
The Opening/Closing Reports option must be programmed as YES. See the XRSuper6/XR20/XR40 Programming
Guide (LT-0305).
17.2 Automatic bell test
This option must be programmed as YES. See the XRSuper6/XR20/XR40 Programming Guide (LT-0305).
17.3 Proprietary dialer
The Model XRSuper6/XR20/XR40 provides Grade A proprietary service when configured as a digital dialer.
Common
Normally Closed
Normally Open
+
Ð
+
Ð
Voltage output
from terminal 11
Voltage output
from terminal 11
Zone activated
annunciator output
Zone activated
annunciator output
Device Fail LED
1k Ohm
Seitenansicht 17