XR500 Series Programming Guide Digital Monitoring Products
9
CommuniCation
Enter R as the rst character for rotary (pulse) phone function. The R character counts as
part of the 32 allowable characters.
Call Waiting: You can place the “* 7 0 P” (Star, Seven, Zero, Pause) in the telephone
number rst position to cancel Call Waiting. For example, program NET with second line
DD and phone number *70P555-1212, and you have NET with Call Waiting cancelled on
the second line.
Caution: A call waiting cancel programmed on a non-call waiting telephone line would
prevent communication to the central station.
3.17
SECOND PHONE NO.
Second Telephone Number
The panel dials the second number when two successive tries using the rst number fail.
If the panel cannot reach the receiver after two attempts using the second number, it
returns to the rst number and makes two additional attempts. A total of ten dialing
attempts are made using the rst and second phone num bers.
Each number can be up to 32 characters in length in cluding any P or R char acters entered
for pause or rotary connections or call waiting cancel option.
Should all ten attempts fail, the panel continues to attempt sending the message using
the next programmed path. If all programmed communication paths fail, the panel clears
the communication buffer and makes one communication attempt each hour to send
a TRANSMIT FAILED (S87) report to the receiver. Access the User Menu Display Events
feature to view the report information not sent to the receiver or download the report
with DMP Remote Link™ software.
3.18
ADVANCED? NO YES
Advanced Programming
Select Yes to enter the Advanced Programming menu for the communication path
currently being programmed.
3.19 First GPRS APN
Enter the rst APN (Access Point Name). This allows an access point for cellular
communication and is used to connect to a DNS network. The APN may contain two lines
of 16 characters to equal 32 characters. Default is set to SECURECOM400.
Note: This option is not used when a 463C or 464-263C CDMA Cellular Communicator
is used for communication.
Second GPRS APN
Enter the second APN (Access Point Name). This works as a backup in case the rst APN
fails. The APN may contain two lines of 16 characters to equal 32 character Default is set
to SECURECOM400.
Note: This option is not used when a 463C or 464-263C CDMA Cellular Communicator
is used for communication.
3.20
FAIL TEST HRS: 0
Fail Test Hours
This option sets the frequency for a Backup or Adaptive path to send a test report when
the closest previous path fails within its path group.
For example, if a backup path is programmed to send a weekly test report and the
Fail Test Frequency is set to 2 hours, when the previous path fails within its group,
the backup path starts sending a test every 2 hours until the previous path restores.
If Fail Test Frequency is set to 0, test reports are sent only according to Test Report
programming. Range is 0 to 24 hours. Default is 0.
3.21
PROTOCOL: TCP
Protocol
This option displays only when Communication Type is NET.
Select TCP to communicate over the network using TCP protocol. Select UDP to
communicate using UDP protocol. Default is TCP.
3.22
RETRY SECONDS: 6
Retry Seconds
This option displays for NET or 232 Communication Types.
Enter the number of seconds (between 6 and 15) the panel should wait before retrying to
send a message to the receiver if an acknowledgment was not received. The panel retries
as many times as possible for a period of one minute before sending a network trouble
message. For example, if retry time is set to 15, the panel retries four times. The default
Retry Time is 6 seconds.
Note: If TCP is enabled, the minimum Retry Time programmed is 6 seconds.
SECURECOM400
-
FIRST GPRS APN
SECURECOM400
-
SECOND GPRS APN