XR500 Series Programming Guide Digital Monitoring Products
7
CommuniCation
Communication
3.1
COMMUNICATION
Communication
Congure the communication options for the panel. The information you program varies
with the Communication Type you select.
3.2
ACCOUNT NO: 12345
Account Number
The Account Number is a 1 to 5 digit number used to identify which panel is sending a
message. Enter the account number sent to the SCS-1R Receiver. Messages may be sent
to a central station or via PC Log Reports to a PC. The default is 12345.
NET, CELL, 232 and DD - The range of valid account numbers for a panel is 1 to 65535.
For accounts of four digits or less, do not enter leading zeros.
CID - Choose an account number between 1 and 9999.
3.3
XMIT DELAY: 30
Transmit Delay
Enter the number of seconds (15 to 45) the panel waits before sending burglary
zones (Night, Day, or Exit) reports to the receiver. Other zone type reports are sent
immediately. Alarm bells and relay outputs are not delayed during this period. Program
Burglary Outputs for pulsed or steady, and set Abort Reports to YES if Opening and Closing
reports are not being sent. Enter 0 (zero) to disable this function. The default is 30.
If the area where the alarm occurred is disarmed during the Transmit Delay time, only an
Abort Report (S45) message is sent to the receiver. If the area where the alarm occurred
is disarmed after the alarm message is sent to the receiver but before the Bell Cutoff
time expires even if the alarm was silenced, an Alarm Cancelled (S49) message is sent.
Otherwise the alarm is sent at the end of the delay. The Alarm Cancelled report cannot
be disabled.
Note: For Commercial Burglary Installations, the combined Transmit Delay
(Abort Window) and Entry Delay must not exceed one (1) minute.
3.4 Communication Path
Up to eight communication paths may be programmed. Each path is designated as a
primary or backup communication route. Path 1 is always Primary but other paths may be
programmed as additional primary or backup.
Each primary path establishes a new path group. A path group is made up of the primary
path and its subsequent backup paths. Typical communication takes place on the primary
path with backup paths being used only when the primary path fails or when the backup
path is programmed to duplicate messages. There is no option to backup path 8.
3.5
COMM TYPE: DD
Communication Type
Species the communication method the panel uses on this path to report system events
to DMP SCS-1R Receivers or non-DMP receivers. Default is DD for Path 1, and NONE for
Path 2-8.
NONE DD NET CID
NONE - For local systems. Selecting NONE ends communication programming.
DD - Digital Dialer communications to a DMP SCS-1R Receiver.
NET - Network communication using the panel onboard network connection. The DMP
Network/Output reporting format is transmitted over a data network to the SCS-1R
Receiver.
CID - This option allows the panel to communicate to non-DMP receivers using the
Contact ID format.
CELL - This option allows communication over the cellular network using the 463G, 463C,
464-263C, 464-263H or CellComRT Cellular Communicators.
232 - This option sends serial data and can be used for radio backup or other
communication options, and uses the on-board serial port.
Select 232 when using a 462N Interface Card or DB-9 backup communications by directly
connecting to the RS-232 port on the panel. If using the on-board RS-232 port, set the
XR500 Series panel J23 jumper to R and briey reset the panel using the J16 jumper to
activate RS-232 operation. Refer to the XR500 Series Installation Guide (LT-0681).
3.6
PATH TYPE: BACKUP
Path Type
The Path Type denes if the path is Primary or Backup. Because Path 1 is Primary, this
option only displays for paths 2-8. Default is Backup.
Note: If the Primary Communication Type is CELL, then the backup Communication Type
can only be NET or 232.
PATH: -
CELL 232
PRIMARY BACKUP