12.15 AUTOMATIC ARMING - Selecting YES allows this area to arm automatically
according to permanent, temporary, or extended schedules.
If closing check is selected as YES, the automatic arming function does not take
place until the expiration of a ten minute closing check delay. See section 12.7. If
the area has been disarmed outside of any permanent or temporary schedule,
the closing check sequence occurs one hour after the area is disarmed.
At arming, bad loops are handled according to the option selected in section
12.16. If a closing report is sent, the user number is indicated as SCH on the
SCS-1 Receiver.
NO disables automatic arming by schedule for this area.
12.16 BAD LOOPS - At the time of automatic arming, some loops in the area may not
be in a normal condition. This option allows you to program the panel's response
to these bad loops. This option is not displayed if AUTO ARM is NO.
BYP - All bad loops are bypassed. A report of the bypass is sent to the receiver if
bypass reports has been selected as YES. See section 6.3. The report indicates
SCH as the user number.
FORC - All bad loops are force armed. Loops force armed in a bad condition are
capable of restoring and reporting an alarm if tripped. A report of the forced loop
is transmitted if Bypass Reports has been selected as YES. See section 6.3. The
report indicates SCH as the user number.
REF - The automatic arming is refused and no arming takes place. A No Closing
report is sent to the receiver regardless of the Closing Check selection. See
section 12.7.
12.17 AUTOMATIC DISARMING - NO disables automatic disarming by schedule for
this area. When YES is selected, the area automatically disarms according to
permanent or temporary schedules. If an opening report is sent to the receiver,
the user number is indicated as SCH.
12.18 ARMED OUTPUT NUMBER - Enter the output to turn on when this area is
armed. The output is turned off when this area is disarmed. The output cannot be
turned on from the Outputs On/Off option of the User Menu.
12.19 BANK SAFE AND VAULT - NO disables the Bank Safe and Vault feature for this
area. When selected as YES, schedules set for this area and the time of day
cannot be changed while the area is armed.
Program schedules before arming:
A Bank Safe and Vault area can only be
disarmed during scheduled times. If you arm the area before programming a
schedule, the panel must be reset to disarm the area or the Bank Safe and Vault
option in Loop Programming must be turned to NO.
Loops in areas programmed for Bank Safe and Vault cannot be bypassed or
force armed.
12.20 COMMON AREA - Select YES to enable this area to operate as a common area.
This area is armed when the last area in the partition is armed and is disarmed
when the first area in the partition is disarmed. You can have multiple common
areas in each partition.
BYP FORC REF
BAD LOOPS: BYP
AUTO ARM NO
AUTO DIS NO
BANK/SAF NO
OUTPUT NO: 0
COMMON NO
12-AREA INFORMATION