Digital Monitoring Products 1912XR Installationsanleitung Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 42
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
Digital Monitoring Products, Inc.
1912XR Programming
Page 8
3.2B EXISTING PRINTER - One or more options in Printer Reports has been enabled.
See section 11.1. You must remove any Printer Reports programming before
using the DNET option to interface with a data network.
3.3 2ND PHONE LINE - Allows you to use a second phone line to send reports to the
SCS-1 Receiver should the first phone line fail. If 2ND LINE is YES, you'll need
to install a DMP 893 Dual Line Module to connect both the main and secondary
phone lines. The 893 provides supervision of both phone lines.
Both DD and MPX type systems can be backed up with a dialer or cellular line.
Multiplex lines cannot be used as a secondary line.
NONE - A second line is not used.
DD - Dialer communication to a DMP SCS-1 Receiver.
CELL - Cellular communication with Cell-Miser™ restrictions. When Cell-Miser is
selected, the following call restrictions apply to the panel.
1. Only loop alarms, Ambush, Line 1 Trouble, Abort, Recall Test, and Delayed
Events can be sent over the cellular system. Delayed Events are only sent
if the cellular call was made for one of the other allowed reports.
2. Line 1 Trouble in sent only once during each armed period.
Area code selection for cellular communication:
Version 1912XR/112 firmware allows you to
enter a letter "C" in the first or second phone number in the panel's Communication section of the
Programmer. When entered, the characters before the "C" are only used when a 2nd LINE Cellular
call is being made. All other calls made on the main line will only use the characters entered after
the letter "C". The letter "C" is never dialed and is recognized by the panel as a marker only.
HST (HOST) - DTE asynchronous communication to a DMP SCS-1 Receiver or
Host automation system. If HST is selected as the Communication Type in
section 3.2, HST will not be displayed as an option in 2ND LINE. If HST is
selected for 2ND LINE, all loop alarms and restorals are duplicated on the
asynchronous channel in addition to the main communication method.
When HST is used as the main or 2ND LINE communication method, the
account number must not begin with a number that matches a line number being
used for multiplex service on the same SCS-1 Receiver. This allows the
Redisplay Non-Restored status list to work properly in receivers with SCS1/805
firmware.
3.3A TEST FREQUENCY - Specifies the communication test interval for the second
phone line. This is displayed if 2ND LINE is programmed as DD or CELL.
NONE - No communication test is made on the second line.
REG - A 2ND LINE communication test is made each time the regular
communication test is completed.
7 - A communication test is made every 7 days at the test time programmed for
the regular communication test. Test time deferrals are disregarded.
30 - A communication test is made every 30 days at the test time programmed
for the regular communication test. Test time deferrals are disregarded.
If the 2ND LINE test fails to communicate after 10 attempts, the regular communication channel
sends a WARNING: PANEL BACKUP COMMUNICATION FAIL (S12) report. The next time the
panel sends a report over the 2ND LINE, the regular communication channel sends a BACKUP
COMMUNICATION LINE RESTORED (S04) report.
3-COMMUNICATION
NONE DD CELL HST
2ND LINE: NONE
NONE REG 7 30
TEST FREQ: NONE
EXISTING PRINTER
Seitenansicht 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 41 42

Kommentare zu diesen Handbüchern

Keine Kommentare