Digital Monitoring Products XT50 Installationsanleitung Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 55
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
XT Series Programming Guide Digital Monitoring Products
7
COMMUNICATION
Communication
3.1 Communication
The Communication section allows you to congure the communication settings for the
XT30/XT50 panel. After choosing the Communication Type, continue through the list of
options.
3.2 Account Number
Enter the account num ber sent to the receiver.
DD, NET, CELL - The range of account numbers for Digital Dialer, Network, and Cell is 1
to 65535. For account numbers of four digits or less, you do not have to enter leading
zeros. The panel automatically right justies the account number.
CID - The account number range for this format is 1 - 9999.
3.3 Transmission Delay
Enter the number of seconds (15 to 45 seconds) the panel waits before sending burglary
alarm reports to the receiver. The bell and relay outputs are not delayed during this
period. Program Burglary Outputs for steady, and set Abort Reports to YES if Opening and
Closing reports are not being sent. Enter 0 (zero) to disable this function. The default is
30.
If the area where the alarm occurred is disarmed during the Transmit Delay time, only
an Abort Report (S45) message is sent to the receiver. If the area where the alarm
occurred is disarmed after the alarm message is sent to the receiver but before the Bell
Cutoff time expires, even if the alarm was silenced, an Alarm Cancelled (S49) message is
sent. The Alarm Cancelled report cannot be disabled.
3.4 Communication Type
This species the communication method the panel uses to contact the receiver. Press
any Select key to display the following communication options:
DD - Digital Dialer communication to DMP SCS-1R or SCS-VR Receivers.
CID - Contact ID dialer communication to non-DMP receivers. This format sends the
report codes of the Ademco Contact ID communication format.
NET - Network communication to DMP Model SCS-1R Receivers.
CELL - Cellular communication to DMP Model SCS-1R or SCS-VR Receivers.
NONE - For local systems. Selecting this ends communication programming.
NOTE: The Backup Dialer, Backup Cellular, Check-in Minutes, and Failed Minutes options
revert to their default values when the communication type is changed. All other
communication programming items remain at their programmed values.
3.5 Backup Dialer
Backup Dialer option is available if COMM TYPE is set for NET. The Backup Dialer tries
to send the message after the main communication fails for 60 seconds on NET. If the
backup dialer fails then the message is discarded.
3.6 Backup Cellular
Backup Cellular option is available if COMM TYPE is set for NET or DD/CID. The Backup
Cellular tries to send the message after the main communication fails for 60 seconds
on NET and 10 dial attempts with DD/CID. If the backup dialer fails then the message is
discarded.
3.7 Test Time
Press COMMAND to enter the Test Time. Enter the time of day the panel sends the test
report to the SCS-1R Receiver. Use entries between 12:00 to 11:59 and then choose AM
or PM.
3.8 Test Days
Enter how often the panel test report is sent to the receiver for each communication
type programmed. Enter from 1 to 60 days. Enter zero to disable the test report. Default
is 1 (one) day. These options only display if a test time is entered and that particular
communication method is being used.
COMMUNICATION
ACCOUNT NO:
XMIT DELAY: 30
COMM TYPE: DD
DD CID NET CELL
NONE
BACKUP DIALER
NO YES
BACKUP CELL
NO YES
TEST TIME
00:00 AM PM
NET TEST DAYS: 1
DIAL TST DAYS: 1
CELL TST DAYS: 1
Seitenansicht 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 54 55

Kommentare zu diesen Handbüchern