Digital Monitoring Products XR100 Series Installation Guide
18
INSTALLATION
XR100 Series Installation Guide Digital Monitoring Products
19
INSTALLATION
J1 Ethernet Connector (XR100N only)
16.1 Description
The J1 Ethernet Connector is available on the XR100N Network version to connect directly to an Ethernet network
using a standard patch cable.
16.2 Ethernet LEDs
The two LEDs, located to the left of J1 Ethernet Connector, indicate network
operation. The top, Link LED ashes green to indicate the network trafc is good.
The bottom, Activity LED ashes yellow to indicate messages are being sent and
received.
J3 Telephone RJ Connector
17.1 Description
Connect the panel to the public telephone network by installing a DMP 356 RJ Cable between the panel J3 connector
and the RJ31X or RJ38X phone jack.
17.2 J10 893A Connector
Connect an 893A Dual Phone Line Module to J10 on the XR100 Series. Refer to the 893A Installation Sheet
(LT-0135) for complete information.
17.3 Notication
The user must not repair registered terminal equipment. In case of trouble, immediately unplug the device from the
telephone jack. The factory warranty provides for repairs. Registered terminal equipment may not be used on party
lines or in connection with coin telephones. Notify the telephone company with the following information:
a. The particular line(s) where the service is connected
b. The FCC registration number as listed in Section 18.1
c. The ringer equivalence
d. The device make, model, and serial number
17.4 Phone Line Monitor
The XR100 Series panel has a built-in telephone monitor that monitors the phone line voltage to verify the
connection to the central ofce. Figure 9 and the table below identify the phone block pin layout, wire numbers,
and colors.
Wire Number Wire Color
1 Gray
2 Orange
3 Black
4 Red
5 Green
6 Yellow
7 Blue
8 Brown
The wires on the RJ31 that feed pins 4 and 5 should be the ONLY wires on the D-marc. All other house phone wiring
should be tied to pins 1 and 8 coming back from the RJ31.
Dial tone must come into RJ31X on pins 4 and 5 and go back to house phones from pins 1 and 8. Follow these steps
to determine if panel is seizing the line:
1. Unplug phone cord from RJ31X
2. Place butt-set on pins 4 and 5
3. Listen for dial tone. With dial tone present, lift either wire from pins 1 or 8
4. Listen for dial tone again. If the dial tone is present, RJ31X wiring is correct. If no dial tone is present, the
RJ31X wiring is backwards. Rewire so dial tone is coming IN on 4 and 5.
If you still have trouble with the phone line, you may need to replace the RJ cord. If the dial tone is still not
present, swap out the RJ31X phone block.




 




Figure 8: Phone Jack Wiring
Figure 7: J1 Header and LEDs