System Link User’s Guide
90
Panel Connection Error: Timeout trying to initiate connection with receiver
.
System Link cannot get a reply from the receiver. Check the following settings and items:
• In System > Configure > System Link check the COM port in the Receiver Tab.
• Check the connection between receiver and computer
• Verify that the proper cables are being used with the proper connector pinout.
• Verify that the receiver is getting power
Panel Connection Error: Invalid connect response while calling panel
. System Link
did not receive proper reply from panel. Try again.
Errors that Occur After the Physical Connection is Established
The following messages may occur after the connection has been made with the panel, yet
the panel and System Link cannot communicate.
Panel Connection Error: Timeout.
System Link did not receive a reply from panel.
Panel Connection Error: Invalid connect response.
System Link did not receive the
proper reply from panel.
Panel Connection Error: Receiver not authorized to connect.
(-VA) This error
message only applies to 1512,1812, 1912, and XR200 Command Processor™ Panels.
For 1512, 1812, and 1912 panels, the user must enter a valid User Code at the Remote
Authorize menu. Disable this by ‘turning off’ Remote Authorize in panel’s Menu Display,
which can only be programmed using a keypad.
For XR200 panels, program Service Receiver to Yes. Go to Program > Remote
Options and select Yes from the drop-down menu next to Service Receiver. If Service
Receiver is No, this message will appear when attempting to connect to the panel.
Panel Connection Error: Invalid receiver number.
(-VR) The receiver key in the
receiver that you are using does not match the previously stored key in the panel’s Alarm
Receiver or Service Receiver location of Remote Options. Use the correct receiver
key (programmed thru System > Configure > SCS-1 System) or program Service
Receiver as Yes in Remote Options of the panel’s programming.
Panel Connection Error: Invalid connect sequence.
(-VD)
Panel Connection Error: Invalid remote key.
(-VC). Panel’s Remote Key does not
match the Remote Key in the Panel Information window. Be sure that the Remote
Key in the Panel Information window is the same as that programmed in the panel.
Panel Connection Error: Panel busy with other communication.
(-VB)
Panel Connection Error: Panel not connected.
(-VN)
Error requesting max partitions.
System Link could not get the max partitions from the
panel.
Connection cancelled.
Action aborted by user.