Digital Monitoring Products 7063A Installationsanleitung Seite 20

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 65
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 19
Digital Monitoring Products XR500 Series Installation Guide
12
InstallatIon
Standby Battery Power Calculations Standby Current Alarm Current
736P POPIT Interface Module
Radionics Popex, POPITs, OctoPOPITs
Qty _______
Qty _______
x
x
25mA
___mA
______
______
Qty _______
Qty _______
x
x
25mA
___mA
______
______
738A Ademco Wireless Interface Module Qty _______ x 75mA ______ Qty _______ x 75mA ______
710 Bus Splitter/Repeater Module Qty _______ x 32mA ______ Qty _______ x 32mA ______
710F Fire Bus Splitter/Repeater Module Qty _______ x 40mA ______ Qty _______ x 40mA ______
711 Zone Expansion Module
Active Zone (EOL Installed)
Qty _______
Qty _______
x
x
11mA
1.6mA
______
______
Qty _______
Qty _______
x
x
11mA
*2mA
______
______
714 Zone Expansion Module
Active Zones (EOL Installed)
Qty _______
Qty _______
x
x
7mA
1.6mA
______
______
Qty _______
Qty _______
x
x
7mA
*2mA
______
______
712-8 Zone Expansion Module
Active Zones (EOL Installed)
Qty _______
Qty _______
x
x
17mA
1.6mA
______
______
Qty _______
Qty _______
x
x
17mA
*2mA
______
______
714-8, 714-16 Zone Expansion Module
Active Zones (EOL Installed)
Qty _______
Qty _______
x
x
20mA
1.6mA
______
______
Qty _______
Qty _______
x
x
20mA
*2mA
______
______
715 Zone Expansion Module
Active Zones (EOL Installed)
2-Wire Smokes
Qty _______
Qty _______
Qty _______
x
x
x
7mA
4mA
.1mA
______
______
______
Qty _______
Qty _______
Qty _______
x
x
x
7mA
*30mA
.1mA
______
______
______
715-8, 715-16 Zone Expansion Modules
Active Zones (EOL Installed)
2-Wire Smokes
Qty _______
Qty _______
Qty _______
x
x
x
20mA
4mA
.1mA
______
______
______
Qty _______
Qty _______
Qty _______
x
x
x
20mA
*30mA
.1mA
______
______
______
716 Output Expansion Module
Active Form C Relays
Qty _______ x 13mA ______ Qty _______
Qty _______
x
x
13mA
12mA
______
______
717 Graphic Annunciator Module
Annunciator Outputs
Qty _______ x 10mA ______ Qty _______
Qty _______
x
x
10mA
1mA
______
______
521LX, 521LXT Smoke Detectors Qty _______ x 8.8mA ______ Qty _______ x *28mA ______
572 Indicator LED Qty _______ x 20mA ______ Qty _______ x 20mA ______
iCOM, iCOM-E Network Alarm Routers Qty _______ x 78.1mA ______ Qty _______ x 78.1mA ______
Aux. Powered Devices on Terminals 7 and 11
Other than Keypads and LX-Bus Modules
______mA ______mA
This page only Sub-Total Standby
______mA Sub-Total Alarm ______mA
Sub-Totals from previous page Sub-Total Standby
______mA Sub-Total Alarm ______mA
*Based on 10% of active zones in alarm Total Standby ______mA Total Alarm ______mA
Total Standby______mA x number of Standby Hours needed
Total Alarm
______ =
______mA
Total
_______mA-hours
+_______mA-hours
_______mA-hours
X .001
= _______Amp-hrs Required
Refer to section 6.9 for standby battery selection.
Seitenansicht 19